NEON LIGHT

Cable construction
FZ-LSi, blue
  • Tinned copper stranded conductor, strand make-up see table below
  • Silicone core insulation 2GI1 to DIN VDE 0207 part 20
  • Glass-fibre braiding
  • Outer-jacket silicone 2GM1 to DIN VDE 0207 part 21
  • Jacket colour blue
FZ-LS, red
  • adapted to ISO 3808 part 1
  • Tinned copper conductor, 19 x 0,25 mm Ø
  • Silicone core insulation 2GI1 to DIN VDE 0207 part 20
  • Jacket colour red brown, Neon-light-cable, yellow
  • Adapted to DIN VDE 0250 part 1 and part 5
  • Tinned copper stranded conductor 30 x 0,25 mm Ø
  • Silicon core insulation 2GI1 to DIN VDE 0207 part 20
Jacket colour yellow
  • Halogen-free according to IEC 60754-2
  • No flame propagation according to IEC 60332-1
Technical Data FZ-LSi, blue
  • Nominal voltage 16kV
  • Test voltage 20kV
  • Breakdown voltage min. 30kV
  • Ignition voltage (kV eff.)
    0,5mm² = 6Kv : 1,0mm² = 8kV : 1,5mm² = 10kV
FZ-LSi, red
  • Test voltage
    • For 5mm Ø = min. 15kV
    • For 7mm Ø = min. 35kV
Neon-light-Cable, yellow
  • Nominal voltage 3,5 kV, 4,0 kV bzw. 7,5 kV
  • Test voltage 10 kV
  • Specific volume resistivity min. 1012 Ohm x cm
  • Minimum bending radius Approx. 7,5 x cable Ø
  • Radiation resistance Up to 20 x 106 cJ/kg (up to 20 Mrad)
Application

Suitable for use as high-voltage resistant connecting cable for automotive ignition systems exposed to high temperatures and oil burner ignition systems. The main application of this cable is in the lamp and lighting industry, as floodlights, industrial lights, suspended and stand lamps. This cable must be protected in steel tubes or flexible steel tubes made of steel taps before touching plaster.